● Mode: electro-magnetic type
● Residual current characteristics: A,AC,G,S
● Pole No.: 2, 4
● Rated making and breaking capacity: 10lnA
● Rated current(A): 63, 80, 100
● Rated voltage: AC 230/400 Rated frequency: 50/60Hz
● Rated residual operating current IAn(A): 0.03, 0.1, 0.3, 0.5
● Rated residual non operating current lAno: 0.5IAn
● Rated conditional short-circuit current Inc: 10kA
● Rated conditional residual short-circuit Current I Ac: 10kA
● Residual tripping current range: 0.5IArH An
● Terminal Connection Height: 19mm
● Electro-mechanical endurance: 4000 cycles
● Connection capacity: Rigid conductor 25mm2
● Connection terminal: Screw terminal
● Pillar terminal with clamp
● Fastening torque: 2.0Nm
● Installation:
● On symmetrical DIN rail 35mm
● Panel mounting
● Protection class:IP20
Construction and Feature
● Elegant appearance; cover and handle in arc shape make comfortable operation.
● Contact position indicating window Transparent cover designed to carry label.
● In case of overload to protected circuit, RCCB handle trips and stays at central position, which enables a quick ● solution to the faulty line. The handle cannot stay in such position when operated manually.
● Provides protection against earth fault/leakage current and function of isolation.
● High short-circuit current withstand capacity
● Applicable to terminal and pin/fork type busbar connection
● Equipped with finger protected connection terminals
● Fire resistant plastic parts endures abnormal heating and strong impact
● Automatically disconnect the circuit when earth fault/leakage current occurs andexceeds the rated sensitivity.
● Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
Technical Data
● Mode: electro-magnetic type
● Residual current characteristics: A,AC,G,S
● Pole No.: 2, 4
● Rated making and breaking capacity: 10lnA
● Rated current(A): 63, 80, 100
● Rated voltage: AC 230/400 Rated frequency: 50/60Hz
● Rated residual operating current IAn(A): 0.03, 0.1, 0.3, 0.5
● Rated residual non operating current lAno: 0.5IAn
● Rated conditional short-circuit current Inc: 10kA
● Rated conditional residual short-circuit Current I Ac: 10kA
● Residual tripping current range: 0.5IArH An
● Terminal Connection Height: 19mm
● Electro-mechanical endurance: 4000 cycles
● Connection capacity: Rigid conductor 25mm2
● Connection terminal: Screw terminal
● Pillar terminal with clamp
● Fastening torque: 2.0Nm
● Installation:
● On symmetrical DIN rail 35mm
● Panel mounting
● Protection class:IP20